When a PowerEdge server raises an alert, a quick way to see what is wrong is often a few racadm commands against its iDRAC9. Every command in this guide only reads: system information, sensor readings, the System Event Log (SEL), the Lifecycle Log, firmware inventory and RAID status. They are safe to run on production servers. The syntax is copied from the iDRAC9 RACADM CLI Guide 7.xx. Output fields can differ slightly between firmware versions. For configuration commands (network, users, BIOS, RAID creation, firmware), see Configure Dell PowerEdge iDRAC with racadm.
Before you start
- Choose how you will run racadm. SSH to iDRAC (firmware racadm): type the commands at the
racadm>>prompt without theracadmprefix. Remote racadm: install Dell iDRACTools on your workstation. Local racadm: install iDRACTools in the server's own OS. - Where you can, use a dedicated monitoring account instead of root. SupportAssist collection also requires accepting Dell's EULA once (see that section).
- For remote racadm, put the connection options before the subcommand, as shown below.
racadm -r 192.0.2.10 -u monitor -p 'xxxx' getsysinfo
racadm -r 192.0.2.10 -u monitor -p 'xxxx' getsysinfo --nocertwarn
--nocertwarn hides the certificate warning when iDRAC still uses its self-signed certificate.
Step 1 — Identify the server and its overall state
racadm getsvctag
racadm getsysinfo
racadm getversion
racadm getremoteservicesstatus
getsvctagprints the Service Tag, which you need for any Dell support case.getsysinfoshows the iDRAC firmware, MAC address, DNS name, IPv4/IPv6 settings and system information. Options:-diDRAC only,-ccommon settings,-4or-6for IP settings,-Awithout labels (for scripts). Host name and OS fields are accurate only with OMSA installed, except for VMware and Windows OS names.getversionlists BIOS, iDRAC and Lifecycle Controller versions. Narrow it with-b(BIOS),-c(CPLD) or-f idrac,-f lc,-f bios.getremoteservicesstatusshows the host status (for example Out of POST, halted at an F1/F2 error prompt, no bootable device) and whether Lifecycle Controller is Ready. Run it before any inventory or export command.
Step 2 — Read the sensors
racadm getsensorinfo
racadm getsensorinfo -c
This shows the status of the system sensors, grouped by type: power, temperature, fan, current, processor, memory, battery, intrusion, redundancy and others, depending on the model. -c gives a compact layout. Look for any sensor that is not OK, and for PSU or fan redundancy that is no longer Full. For fan and temperature alerts, see troubleshooting fan and thermal alerts.
Step 3 — Read the System Event Log and the iDRAC log
racadm getsel -i
racadm getsel -o
racadm getsel -s 1 -c 20
racadm getraclog -c 20
getsel -icounts the SEL entries.-oprints one record per line, which is good forgrep.-sand-cchoose the starting record and how many to show.--morepages the output (press Q to quit).getraclogshows iDRAC's own log: logins, failed logins and licence messages, with message IDs such asUSR0005. Local racadm returns 100 records by default.
Step 4 — Filter the Lifecycle Log
The Lifecycle Log records hardware events, configuration changes, updates and audit entries. lclog view filters it by category (System, Storage, Worknotes, Config, Updates, Audit), by severity (Critical, Warning, Info), by time or by text:
racadm lclog view -i
racadm lclog view -c storage,system -s warning,critical
racadm lclog view -n 20
racadm lclog view -k session
racadm lclog view -r "2026-10-01 00:00:00" -e "2026-10-31 23:59:59"
If a remote query returns nothing, Dell suggests asking for fewer records or raising the remote racadm timeout. To archive the whole log (for example for Dell support), export it to a share:
racadm lclog export -f lclog.xml.gz -u user -p pass -l //192.0.2.20/logs --complete
For reading the entries and message IDs, see iDRAC9 SEL and Lifecycle Log.
Step 5 — Check RAID controllers, virtual disks and drives
The storage subcommand (also accepted as raid) reads the status of the storage controllers, virtual disks, enclosures and drives that iDRAC manages:
racadm storage get status
racadm storage get controllers -o -p name,status
racadm storage get vdisks -o -p layout,status
racadm storage get pdisks -o -p State
racadm storage get batteries --refkey RAID.Integrated.1-1 -o -p status,state,name
-oprints full objects with their properties.-plimits the output to the properties you name (up to 10).--refkeyscopes the query to one controller or enclosure (up to 3 FQDDs). First runracadm storage get controllersto list the FQDDs on your server, such asRAID.Integrated.1-1orRAID.SL.3-1.- Controller fields include Status, RollupStatus, firmware and driver version and patrol read state. Drive output includes State, Status, FailurePredicted, MediaType and, for SSDs, RemainingRatedWriteEndurance.
- Run
racadm storage help getfor every object type and its properties.
A degraded virtual disk or a drive with FailurePredicted = YES needs action. See degraded or offline virtual disks. From inside the OS, perccli status commands give the same information.
Step 6 — Firmware inventory and jobs
racadm swinventory
racadm hwinventory
racadm jobqueue view
swinventory lists each component's FQDD, current version and, where one is stored, the previous version. hwinventory lists the hardware inventory by device. jobqueue view shows pending and completed jobs, such as a firmware update stuck in Scheduled.
Step 7 — Collect a SupportAssist bundle for Dell
racadm supportassist accepteula
racadm supportassist collect -t sysinfo -l //192.0.2.20/logs -u user -p pass
racadm supportassist exportlastcollection -l //192.0.2.20/logs -u user -p pass
collect exports to the share given with -l, and exportlastcollection re-exports the last bundle. Log types for -t include sysinfo (system information), ttylog (storage logs), osAppAll (OS and application data, needs the iDRAC Service Module), Debug and TelemetryReports. The guide notes that register, collect -upload and the auto-collection scheduler are not supported on iDRAC 7.00.00.00 and later. The full workflow is in SupportAssist collection from iDRAC9.
Frequently asked questions
Do these commands change anything on the server?
No. They only display information. The export and SupportAssist commands write a file to the share you name, and the server keeps running.
Why are host name and OS blank in getsysinfo?
Dell notes that these fields need OpenManage Server Administrator in the OS. The exception is VMware and Windows OS names, which show anyway.
Checklist
- Access method chosen (SSH, remote or local racadm) with a dedicated account
- Service Tag, versions and LC status captured
- Sensors checked for anything not OK and for lost redundancy
- SEL and Lifecycle Log filtered for Critical and Warning events
- Controller, virtual disk and drive status reviewed
- SupportAssist bundle exported if you are opening a Dell case